ASTM C 1294 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials

Zoom  Zoom Issue Date:2012-02-08   Browse:1013
ASTM C 1294绝缘玻璃密封条与液体外加玻璃材料的混用性的标准试验方法
ASTM C 1294 Standard Test Method for Compatibility of Insulating Glass Edge Sealants with Liquid-Applied Glazing Materials
ASTM C 1294绝缘玻璃密封条与液体外加玻璃材料的混用性的标准试验方法
 
Liquid-applied glazing materials, bedding sealants, glazing compounds (that is, glazing sealants) are designed to provide a seal between the IG unit and the window or wall framing. Frequently there is physical contact between these materials and an IG unit edge sealant. Depending on the particular IG unit edge sealant, there can be a detrimental physical or chemical interaction between it and the liquid-applied glazing material. Detrimental effects may include: weakening, softening, hardening, or adhesive failure of the IG edge sealant, or visual obstruction inside the IG unit.
1. Scope
1.1 This test method covers a laboratory procedure for quantitatively measuring the compatibility of liquid-applied glazing materials with an insulating glass unit edge sealant. Compatibility is determined by measuring the changes in the insulating glass edge sealant adhesive and cohesive properties. Hereinafter insulating glass is referred to as IG.
1.2 This test method does not address the issue of the integrity of the hermetic seal or changes to the vision area in an IG unit. Such factors as possible unit fogging or primary sealant reaction in a dual-seal system due to volatile components permeating the IG sealant are not considered in this test method.
1.3 The committee with jurisdiction over this standard is not aware of any comparable standards published by other organizations.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
C717 Terminology of Building Seals and Sealants
C1265 Test Method for Determining the Tensile Properties of an Insulating Glass Edge Seal for Structural Glazing Applications
 
Index Terms
bedding sealant; compatibility; glazing sealant; insulating glass; sealant; Adhesion--sealants; Bedding sealant; Cohesion--sealants; Compatibility--sealants; Glazing compounds/applications; Insulating glass (IG); Sealants;
 
 