EN 45545-2 Fire test to cable

Zoom  Zoom Issue Date:2014-08-05   Source:Firetc   Browse:1873

EN 45545-2 Fire test to cable- Standard 

EN45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviours of materials and components - R15 / R16

 EN 45545-2 Fire test to cable- General 

Electrical cables which satisfy the fire safety requirements of EN 50306, EN 50264 or EN 50382 are considered to satisfy the requirements of R15 and R16 for the corresponding hazard level (no further testing required).

 EN 45545-2 Fire test to cable - Requirement

 EN 45545-2 R15 Cables for interior 

Test Method

Requirement

HL1

HL2

HL3

EN 60332-1-2

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

EN 60332-3-24

D12mm

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.1

6 < D < 12 mm

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.2

D ≤ 6 mm

<1.5m

<1.5m

<1.5m

EN 61034-2

-

>25%

>50%

EN 50305

Clause 9.2 ITC

<10

<10

<6

 EN 45545-2 R16 Cables for exterior 

Test Method

Requirement

HL1

HL2

HL3

EN 60332-1-2

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

EN 60332-3-24

D12mm

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.1

6 < D < 12 mm

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.2

D ≤ 6 mm

<1.5m

<1.5m

<1.5m

EN 61034-2

>25%

>50%

>70%

EN 50305

Clause 9.2 ITC

<10

<10

<6

 EN 45545-2 Fire test to cable Reference Standard

 EN 50306 Railway rolling stock cables having special fire performance

EN 50264 Railway rolling stock power and control cables having special fire performance

EN 50382Railway rolling stock high temperature power cables having special fire performance

EN 60332-1-2, Tests on electric and optical fibre cables under fire conditions — Part 1-2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1 kW pre-mixed flame

EN 60332-3-24Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables -Category C

EN 61034-1, Measurement of smoke density of cables burning under defined conditions -Part 1: Test apparatus

EN 61034-2, Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

EN 50305Railway rolling stock cables having special fire performance -Test methods

 
 