Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Inquiry For Fire Testing
 
Recommended Service
Hot Fire test center
 
Your location: Home » Fire test center » Railway Component » Text

DIN EN 50305 / EN 50305 Toxicity test

Zoom  Zoom Issue Date:2014-08-14   Browse:2306
 DIN EN 50305 / EN 50305 Toxicity test 

DIN EN 50305 Toxicity test - Standard 

DIN EN 50305 Railway applications-Railway rolling cables having special fire performance-Test methods, Clause 9.2 Toxicity 

DIN EN 50305 Toxicity test – Test conditions 

Prior to testing, all test pieces was conditioned at least 48 h in an atmosphere having a temperature of 23±2°C and a relative humidity of 50±5%. 

DIN EN 50305 Toxicity test - Requirement 

According to DIN 5510-2 test standard,

Requirements :  I.T.C Values≤ 3Refer to DIN EN 50264-1:2008 

DIN EN 50305 Toxicity test - Critical Concentration 

CCZ Values for varions gased

Gas

CCZ

Carbon Dioxide(CO2)

90 000

Carbon Monoxide(CO)

1750

Hydrogen Cyanide(HCN)

55

Nitrogen Oxides(NO2)

90

Sulphur Dioxide (SO2)

260

DIN EN 50305 Toxicity test – Reference Standard 

DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods. 

EN45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviours of materials and components 

EN60332-3-24: 2010-08 Test on Electric and Optical Fibre Cables under Fire Conditions Part 3-24: Test For vertical flame spread of vertically---Mounted bunched wires or cables Category C (IEC 60332-3-24:2000 + A1:2008) 

DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C 

DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C 

        DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods 

DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame 

DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus

 

 

 

 
 