DIN EN 61034 / EN 61034 Smoke density test - Standard
DIN EN 61034-1:2006-03 Measurement of smoke density of cables burning under defined conditions –Part 1: Test apparatus
DIN EN 61034-2:2006-03 Measurement of smoke density of cables burning under defined conditions –Part 2: Test procedure and requirements
DIN EN 61034 / EN 61034 Smoke density test - Test condition
Before testing, all test pieces was carefully straightened and then conditioned for at least 16 h at 23 °C± 5 °C.
DIN EN 61034 / EN 61034 Smoke density test - Requirement
The value of light transmission allowed within the first 20 min not less than 60%. (Refer to DIN 5510-2 test standard).
DIN EN 61034 / EN 61034 Smoke density test - Test condition
EN45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviors of materials and components
DIN5510-2: Preventive fire protection in railway vehicles; Part 2: Fire behavior and fire side effects of materials and parts, classification, requirement and test methods
EN 61034-1, Measurement of smoke density of cables burning under defined conditions -Part 1: Test apparatus
EN 61034-2, Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements
EN 50305Railway rolling stock cables having special fire performance -Test methods
DIN EN60332-1-2: Test for vertical flame propagation for a single insulated wire or cable
EN60332-3-24: Test on Electric and Optical Fibre Cables under Fire Conditions Part 3-24: Test For vertical flame spread of vertically---Mounted bunched wires or cables Category C
DIN EN 50266-2-5 Common Test Methods for Cables under Fire Conditions - Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or Cables Part 2-5: procedures – Category D