Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Inquiry For Fire Testing
 
Recommended Service
Hot Fire test center
 
Your location: Home » Fire test center » FR Furniture » Text

TB 129: Fire Test for Mattresses for Use in Public Buildings

Zoom  Zoom Issue Date:2014-10-15   Browse:1328
TB 129: Fire Test for Mattresses for Use in Public Buildings - Standard Title

 TB 129:1992 Flammability Test Procedure for Mattresses for Use in Public Buildings 


TB 129: Fire Test for Mattresses for Use in Public Buildings - Standard Brief

 The purpose of this test method is to determine the burning behavior of mattresses used in public occupancies by measuring specific fire-test responses when the mattress is subjected to a specified flaming jgnition source under well ventilated conditions.

         This test method is applicable only to the finished article of mattresses and other complete bedding systems and does not apply to testing of individual component materials used in the construction of bedding systems, such as ticking materials, foams, cotton battings, etc.

         The public occupancies include, but are not limited to health care facilities, old age convalescent and board and care homes, college dormitories and residence halls.

 
  Although this test method is primarily a test for mattresses, other bedding systems may be evaluated using procedures described in Appendix E.

 
TB 129: Fire Test for Mattresses for Use in Public Buildings - Test Clause

 -  Testing of Mattresse
         -  Testing of Bedding Systems: (a) A mattress and foundation; (b) A mattress with bed clothes; (c) A mattress and foundation with bed clothes; (d) Bed clothes only.

 
TB 129: Fire Test for Mattresses for Use in Public Buildings - Test Requirement:


         Weight Loss dut to combustion shall be less 3 pounds in the first 10 min;
 
         The maximum rate of heat release shall be less 100Kw;
 
         The total heat release shall be less 25MJ in the first 10 min.

 

TB 129: Fire Test for Mattresses for Use in Public Buildings - Test Specimen

      -  2 Actual mattresses for each test

       -  TB 129: Fire Test for Mattresses for Use in Public Buildings - Reference Standard:

       -  16 CFR PART 1632—STANDARD FOR THE FLAMMABILITY OF MATTRESSES AND MATTRESS PADS (FF 4–72, AMENDED
- 16 CFR Part 1633 Standard for the Flammability (Open Flame) of Mattresses and Mattress/ Foundation Sets

       -  TB 106 Requirements, Test Procedure and Apparatus for Testing the Resistance of a Mattress or Mattress Pad to Combustion Which May Result from a Smoldering Cigarette

       -  TB 121 Flammability Test Procedure for Mattresses for Use in High Risk Occupancies

       -  NFPA 267 Fire characteristics of mattresses and bedding assemblies exposed to flaming ignition source

-  ASTM E1590 Standard test method for Fire testing of mattresses (open flame)

-  TB 604 Test Procedure and Apparatus for the Open Flame Resistance of Filled Bedclothing

 

 
 
[ Fire test center Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]

 

 
 
Home | About us | Contact | Terms & Conditions | Copyright | Site Map | Friend link | Guestbook | Old Version | 闽ICP备09009213号
©2013-2015 FIRETC.NET All Rights Reserved   ICP:闽ICP备09009213号-4