IEC 6
IEC 6
IEC 6
This part of IEC 60695 specifies the details of the glow-wire test to be applied to test specimens of solid electrical insulating materials or other solid materials for ignitability testing to determine the glow-wire ignition temperature (GWIT).
The test results make ti possible to provide a relative comparison of various materials according to the temperature at which the test specimen ignites during the application of the electrically heated glow-wire used as an ignition source.
The test method is not valid for determining the ignition behaviour of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc, greatly influence the ignitability of the materials used therein. In addition to this, it is not valid for determining fire behaviour and fire hazard of equipment.
IEC 6
The samples shall be stored for at least 48 h at a temperature of (23±2) ℃ and a relative humidity of (50 ±5 ) %.
IEC 6
length: no less than
IEC 6
- IEC 6
- IEC 6
- IEC 6
- UL 94 Test For Flammability of Plastic Materials for Parts in Devices and Appliances
- IEC 6
- ISO 4589-2:1996+A1:2005 Plastics -- Determination of burning behaviour by oxygen index -- Part 2: ambient-temperature test
- ISO 4589-3:1996 Plastics -- Determination of burning behaviour by oxygen index -- Part 3: Elevated-temperature test
- ISO 6722:2006 specifies the dimensions, test methods, and requirements for single-core 60 V cables intended for use in road vehicle applications
- ASTM D 2863 Standard Test Method for Measuring the Minimum Oxygen Concentration to Support Candle-Like Combustion of Plastics (Oxygen Index)