GA 306.1 Classification and requirement for Flame retardant cables – Standard
GA 306.1 Flame retardant and Fire Resistive cables–Classification and requirement for flame retardant and fire resistive characteristics of plastic insulated electric cables–Part 1: Flame retardant cables

GA 306.1 Classification and requirement for Flame retardant cables – Scope
This part of GA 306 specifies the definition, technical requirements, test methods, inspection rules, marking and packaging of plastic insulated flame retardant cables.

This section applies to plastic insulated flame retardant power cables with a rated voltage of 35kV and below, plastic insulated flame retardant control cables with a rated voltage less than 450/750V, and plastic insulated flame retardant cables with a rated voltage up to and including 450 / 750v.

GA 306.1 Classification and requirement for Flame retardant cables – Reference standards

IEC 60754-1 Test on gases evolved during combustion of materials from cables - Part 1: Determination of the halogen acid gas content
EN 50267-2-1 Common test methods for cables under fire conditions—Tests on gases evolved during combustion of materials from cables—Part 2-1:Procedures—Determination of the amount of halogen acid gas
IEC 60754-2 Test on gases evolved during combustion of materials from cables - Part 2: Determination of acidity (by pH measurement) and conductivity
EN 50267-2-2 Common test methods for cables under fire conditions—Tests on gases evolved during combustion of materials from cables—Part 2-2:Procedures—Determination of degree of acidity of gases for materials by measuring pH and conductivity
NES 02-713 Determination of the Toxicity index of the products of combustion from small specimens of materials
IEC 61034 Measurement of smoke density of cables burning under defined conditions
EN 50268-2 Common test methods for cables under fire conditions—Measurement of smoke density of cables burning defined conditions-Part 2:Procedure
EN 50265-2-1 Common test methods for cables under fire conditions— Test for resistance to vertical flame propagation for a single insulated conductor or cable— Part 2-1: Procedures— 1kW pre-mixed flame
NF C 32-070 Insulated conductors and cables for installation-Classification tests on conductors and cables with regard to fire behaviour.

 
 