Fire test center will provide Germany Standard DIN 4102-1 Fire Test to Building Material
DIN 4102-1 fire test to building material
> DIN 4102-1 Fire behaviour of building materials and elements Part 1: Classification of building materials Requirements and testing
DIN 4102-1 fire test to building material - Instruction
This standard defines fire behaviour classes for building materials and specifies requirements and test methods for each class
DIN 4102-1 fire test to building material - Products Scope
> Building material and elements:
Sheet materials (including plates and slabs)
|
Coverings
|
Composite materials
|
Insulation
|
Material assemblies,
|
Coatings
|
Pipes and fittings
|
Curtains
|
Decorative materials
|
Fire retardants
|
Other materials suspended from ceilings
|
Etc.
|
Intumescent coatings
|
> DIN 4102-1 fire test to building material - Classification
When the material's fire behaviour has been determined in accordance with the standard, it divides into:
Building material class
|
Designation
|
|
Class A
|
A1
|
Non-combustible materials
|
A2
|
||
Class B
|
B1
|
Not easily flammable
|
B2
|
Flammable
|
|
B3
|
Easily flammable
|
> DIN 4102-1: Class A
A1: Materials may be classed as A1 materials if they:
- Pass the test specified according the standard corresponding parts
- meet the requirements for class A2 materials
A2: Materials may be classed as A2 materials if they:
- Pass the test specified according the standard corresponding parts
- Pass the test specified DIN 4102-16
> DIN 4102-1: Class B
B1: All materials, except flooring, may be classed as B1 materials if they
- Withstand the test specified in DIN 4102-16 using the ‘Brandschacht’ apparatus specified in DIN 4102-15
- Meet the requirements for class B2 materials.
B2: Materials may be classed as B2 materials if they
- Pass the test specified according the standard corresponding parts
- Flooring materials may be assigned to material class B2 if they meet at least the requirements for class T-b as in DIN 66081.
B3: Combustible materials which cannot be classed as B1 or B2 materials shall be classed as B3 materials
DIN 4102-1 fire test to building material - Reference Standard
> DIN 4102-2: Fire behaviour of building materials and elements - Building components - Concepts, requirements and tests
> DIN 4102-4: Fire behaviour of building materials and elements - Overview and design of classified building materials, elements and components
> DIN 4102-8: Fire behaviour of building materials and elements - Small-scale test furnace
> DIN 4102-14: Fire behaviour of building materials and elements - Determination of the burning behaviour of floor covering systems using a radiant heat source
> DIN 4102-15: Fire behaviour of building materials and elements - ‘Brandschacht’ apparatus
> DIN 4102-16: Fire behaviour of building materials and elements - ‘Brandschacht’ tests
> DIN 18180: Gypsum plasterboard - Types, requirements and testing
> DIN 50014: Artificial climates in technical applications - Standard atmospheres
> DIN 50050-1: Small cabinets for testing the burning behaviour of materials
> DIN 50051 Burners for testing the burning behaviour of materials
> DIN 50055 Light measuring system for testing smoke development
> DIN 51622 Propane, propene, butane, butene and their mixtures – Requirements
> DIN 51900-2 Determination of gross calorific value of solid and liquid fuels using the bomb calorimeter, and calculation of calorific value - Method using the isothermal jacket
> DIN 51900-3 Determination of gross calorific value of solid and liquid fuels using the bomb calorimeter, and calculation of calorific value - Method using the adiabatic jacket
> DIN 53436-1: Toxicity testing of fire effluents - Combustion apparatus and determination of test temperature
> DIN 53436-2: Toxicity testing of fire effluents - Thermal decomposition method
> DIN 53436-3: Toxicity testing of fire effluents - Method of testing inhalation toxicity
> DIN 53438-1: Determining the response of combustible materials to ignition by a small flame – General
> DIN 66081: Classification of the burning behaviour of textile products - Textile floor coverings
> IS0 1716: 1973 Building materials - Determination of calorific potential
> IS0 4783-2: 1989 Industrial wire screens and woven wire cloth - Guide to the choice of aperture size and wire diameter combinations - Part 2: Preferred combinations for woven wire cloth
DIN 4102-1 fire test to building material – Similar standard
> EN ISO 11925-2: Reaction to fire tests – Ignitability of building products subjected to direct impingement of flame – Part 2: Single-flame source test
> EN 13501-1: Fire classification of construction products and building elements- Part1: Classification using data from reaction to fire tests
> NF P 92 - 501: Safety against fire - Building materials - Reaction to fire tests - Radiation test used for rigid materials. or for materials on rigid substrates (flooring and finishes) of all thicknesses. and for flexible materials thicker that 5 mm
> NF P 92 - 503: Safety against fire - Building materials – Reaction to fire tests. Electrical burner test used for flexible materials
> BS 476: Fire tests on building materials and structures
> GB 8624: Classification for burning behavior of building materials and products
> GB 20286: Requirements and mark on burning behavior of fire retarding products and subassemblies in public place