Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Inquiry For Fire Testing
 
Recommended Service
Hot Fire test center
 
Your location: Home » Fire test center » Building Material » Text

NF P92-503: Fire Test to Building Material – M Rating

Zoom  Zoom Issue Date:2011-07-15   Source:Firetc   Browse:3220
NF P92-503, The test involves submitting, under defined conditions, the test pieces to the action of: heat radiation, hot gases sweeping the surface of the test pieces, If require, a pilot flame is used to cause the inflammation of the pyrolysis gas. Th
 
Fire test center will provide French Standard NF P92-503 Fire Test to Building Material

NF P 92-503 Fire test to Building materials - Standard Title
> NF P92-503: Safety against fire: Building materials – Reaction to fire tests. Electrical burner test used for flexible materials

NF P 92-503 Fire test to Building materials - Scope
This document aims to define a method for reaction to fire tests used for:
> flexible material
> tight fitting flexible wall and ceiling coatings of any thickness
> flexible filtering media of any thickness

NF P 92-503 Fire test to Building materials - Principle
The test involves submitting, under defined conditions, the test pieces to the action of:
> heat radiation
> hot gases sweeping the surface of the test pieces
If require, a pilot flame is used to cause the inflammation of the pyrolysis gas.
The time to inflammation, the persistence of the flame, the nature and the effects of combustion are noted.

NF P 92-503 Fire test to Building materials - Test Method
NF P 92-503 M rating test Classify the fire test to M1, M2, M3, M4M0 is the highest class
Observe the following Result in the test and classify the rating
> Burning Time
> Dropping
> Destroyed length

NF P 92-503 Fire test to Building materials – Reference Standard
> NF C 42-321:1987 Appareils de mesurage électriques – Couples thermoélectriques – Tables de reference
> NF C 42-323:1985 Appareils de mesurage électriques – Identification des couples thermoélectriques.
> NF X 15-001:1991 Enceintes et conditions d’essais–Atmosphères normales de conditionnement ou d’essai
> NF X 65-020:1991: Glossaire de termes relatifs au feu et de leurs définitions
> NF P 92-503 Fire test to building material – Similar Standard

Fire Test to Building Material according to French Standard – M Rating (M0,M1,M2,M3,M4)
> NF P 92-510: Determination of upper calorific potential
> NF P 92-501: Safety against fire: Building materials – Reaction to fire tests. used for rigid material or flexible materials thicker than 5mm
> NF P 92-503: Safety against fire - Building materials -Reaction to fire tests - Electrical burner test used for flexible materials
> NF P 92-504: Safety against fire - Building materials - Reaction to fire tests - Flame persistence test and speed of the spread of flame.
> NF P 92-505: Safety against fire - Building materials - Reaction to fire tests - Test used for thermal melting materials - Dripping test.
> NF P 92-506: Safety against fire - Building Material - Flooring
> NF P92-507: Fire safety - Building - Interior fitting materials - Classification according to their reaction to fire