ASTM D495固体电绝缘材料耐高压低电流干电弧性能测试方法

Zoom  Zoom Issue Date:2012-02-07   Browse:1246
ASTM D495固体电绝缘材料耐高压低电流干电弧性能测试方法
ASTM D495 Standard Test Method for High-Voltage, Low-Current, Dry Arc Resistance of Solid Electrical Insulation
ASTM D495固体电绝缘材料耐高压低电流干电弧性能测试方法

1. Scope
1.1 This test method covers, in a preliminary fashion, the differentiation among similar materials with respect to their resistance to the action of a high-voltage, low-current arc close to the surface of insulation, intending to form a conducting path therein or in causing the material to become conducting due to the localized thermal and chemical decomposition and erosion.
1.2 The usefulness of this test method is very severely limited by many restrictions and qualifications, some of which are described in the following paragraphs and in Section . Generally, this test method should not be used in material specifications. Whenever possible, alternative test methods should be used, and their development is encouraged.
1.3 This test method will not, in general, permit conclusions to be drawn concerning the relative arc resistance rankings of materials that may be subjected to other types of arcs: for example, high voltage at high currents, and low voltage at low or high currents (promoted by surges or by conducting contaminants).
1.4 The test method is intended, because of its convenience and the short time required for testing, for preliminary screening of material, for detecting the effects of changes in formulation, and for quality control testing after correlation has been established with other types of simulated service arc tests and field experience. Because this test method is usually conducted under clean and dry laboratory conditions rarely encountered in practice, the prediction of a material's relative performance in typical applications and in varying "clean to dirty" environments may be substantially altered (Note 0). Caution is urged against drawing strong conclusions without corroborating support of simulated service tests and field testing. Rather, this test method is useful for preliminary evaluation of changes in structure and composition without the complicating influence of environmental conditions, especially dirt and moisture. By changing some of the circuit conditions described herein it has been found possible to rearrange markedly the order of arc resistance of a group of organic insulating materials consisting of vulcanized fiber and of molded phenolic and amino plastics, some containing organic, and some inorganic, filler.
1.5 While this test method uses dry, uncontaminated specimen surfaces, Test Method D 2132, Test Methods D 2303, and Test Method D 3638 employ wet, contaminated specimen surfaces. Their use is recommended for engineering purposes and to assist in establishing some degree of significance to this test method for quality control purposes.
1.6 This test method is not applicable to materials that do not produce conductive paths under the action of an electric arc, or that melt or form fluid residues that float conductive residues out of the active test area thereby preventing formation of a conductive path.
1.7 The values stated in inch-pound units are to be regarded as the standard.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific precautionary statements, see , , Section , and .

2. Referenced Documents (purchase separately)
ASTM Standards
D1711 Terminology Relating to Electrical Insulation
D2132 Test Method for Dust-and-Fog Tracking and Erosion Resistance of Electrical Insulating Materials
D2303 Test Methods for Liquid-Contaminant, Inclined-Plane Tracking and Erosion of Insulating Materials
D3638 Test Method for Comparative Tracking Index of Electrical Insulating Materials
D6054 Practice for Conditioning Electrical Insulating Materials for Testing
IEC Standard
IEC61621 Dry Solid Insulating Materials--Resistance Test To High-Voltage, Low-Current Arc Discharges
Index Terms
arc resistance; dry arc resistance; high voltage; low current; stainless steel electrodes; tungsten rod electrodes
 
 