ASTM E2393 Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers

Zoom  Zoom Issue Date:2012-02-08   Browse:1073
ASTM E2393安装的防火接头系统和周围防火壁的现场检验的标准规范
ASTM E2393  Standard Practice for On-Site Inspection of Installed Fire Resistive Joint Systems and Perimeter Fire Barriers
ASTM E2393安装的防火接头系统和周围防火壁的现场检验的标准规范
This practice is intended to provide a standard set of guidelines that are to be followed when conducting and reporting on inspections of installed fire resistive joint systems.
This practice is intended to provide a means to verify compliance of the installed fire resistive joint systems to the inspection documents.
This practice is not intended to provide a basis for selecting installers or products, or both.
This practice is not intended to establish any performance criteria of the inspected fire resistive joint systems.
1. Scope
1.1 This practice covers the establishment of procedures to inspect fire resistive joint systems, including methods for field verification and inspection.
1.2 This practice addresses all types of fire resistive joint systems and of perimeter joint protection.
Note 1—Fire resistive joint system and joint are defined in Test Method E1966 and UL 2079.
Note 2—Perimeter joint protection is defined in Test Method E2307.
Note 3—Fire resistive joint systems include joints between two fire resistive assemblies, and perimeter joints between a fire resistive floor assembly and a non-fire-resistive wall assembly. The application of these systems are sometimes extended based on an evaluation to other types of construction.
1.3 This practice provides methods by which qualified inspectors verify that required fire resistive joint systems on a project have been installed and that their installations are in accordance with the inspection documents.
1.4 The values stated in inch-pound units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
1.6 The text of this standard references notes and footnotes which provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of the standard.

2. Referenced Documents (purchase separately)
ASTM Standards
E176 Terminology of Fire Standards
E631 Terminology of Building Constructions
E699 Practice for Evaluation of Agencies Involved in Testing, Quality Assurance, and Evaluating of Building Components
E1966 Test Method for Fire-Resistive Joint Systems
E2307 Test Method for Determining Fire Resistance of Perimeter Fire Barriers Using Intermediate-Scale, Multi-story Test Apparatus
Other Standard
UL2079 Fire Tests of Fire Resistive Joints
Other Documents
NFPA5000 Building Code
Index Terms
fire resistive joint system; firestopping; inspection; inspector; joint; joint system; Fire barrier; Perimeter fire barrier system; Inspection--buildings; Fire resistance; On-site evaluation/inspection ;

 
 
[ Fire test center Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]

 

 
 
Home | About us | Contact | Terms & Conditions | Copyright | Site Map | Friend link | Guestbook | Old Version | 闽ICP备09009213号
©2013-2015 FIRETC.NET All Rights Reserved   ICP:闽ICP备09009213号-4