-Chinese & International standard
-Best factory price & high quality
-Prompt delivery
(1)The long-time permissible operating temperature is 70oC;
The ambient temperature under installation should not go below 0oC.
(2)a. for non-armoured cable and flexible shielded cable, the bending radius should not be less than 6 times the outer diameter;
b. for armoured or copper-tape shielded cable, the bending radius should not be less than 12 times the outer diameter;
Model |
De |
Application |
KVV |
copper conductor, PVC insulated, PVC sheathed, control cable |
Suitable for being laid indoors, in cable trench, pipelines or other specific occasions. |
KVVP |
copper conductor, PVC insulated, PVC sheathed, braided, shielded, control cable |
Suitable for being laid indoors, in cable trench, pipelines or other specific occasions that demands shielding. |
KVVP2 |
copper conductor, PVC insulated, PVC sheathed, copper-tape shielded, control cable |
|
KVV22 |
copper conductor, PVC insulated, PVC sheathed, steel-tape armored, control cable |
Suitable for being laid indoors, in cable trench and pipelines, directly burial or other specific occasions with a relatively large capacity for mechanical stretching force. |
KVV32 |
copper conductor, PVC insulated, PVC sheathed, thin steel wire-armored, control cable |
Suitable for being laid indoors, in cable trench, pipelines, silo or other specific occasions that demands shielding. |
KVVR |
copper conductor, PVC insulated, PVC sheathed, flexible, control cable |
Suitable for being laid indoors and places that demands moving cables with flexibility. |
KVVRP |
copper conductor, PVC insulated, PVC sheathed, braided shielded, flexible, control cable |
Suitable for being laid indoors and shielded places that demands moving cables |
Type |
Scope of Manufacture |
||||||||
Application Environment | |||||||||
Nominal Cross-section of Conductor |
|||||||||
0.5 |
0.75 |
1 |
1.5 |
2.5 |
4 |
6 |
10 |
||
Cores |
|||||||||
Copper Conductor PVC/PE/XLPE Insulated PVC Sheathed |
_ |
2~61 |
2~14 |
2~10 |
Laid in fixed places, such as indoors, trenches or ducts. | ||||
Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Braided Copper-wire Screened |
_ |
2~61 |
2~14 | 2~10 | Laid in fixed places, such as indoors, trenches or ducts with shield requirements. | ||||
Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Braided Copper-wire Screened, Steel-tape Armoured |
_ | 2~61 | 2~14 | 2~10 | Laid in fixed places, such as indoors, trenches or ducts which can bear much external mechanical force with shield requrements. | ||||
Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Copper-tape Screened |
_ | 2~61 | Laid in fixed places, such as indoors, trenches or ducts with shield requirements. | ||||||
Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Braided Copper-wire Screened, Steel-tape Armoured |
_ | 2~61 | Laid in fixed places, such as indoors, trenches or ducts which can bear much external mechanical force with shield requrements. | ||||||
Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Steel-tape Armoured |
_ | 2~61 | 2~14 | 2~10 | Laid in fixed places, such as indoors, trenches or ducts which can bear much external mechanical pulling force. | ||||
Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Steel-wire Armoured |
_ | 6~61 | 16~61 | 4~14 | 4~10 | Laid in fixed places, such as indoors, trenches tunnels, shafts which can bear much external mechanical pulling force. | |||
Flexible Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed |
2~61 | _ | Laid in indoors with flexible screened requirements. |
||||||
Flexible Copper Conductor PVC/PE/XLPE Insulated, PVC Sheathed, Braided Copper-wire Screened |
2~61 | _ | Laid in indoors with flexible screened requirements. |