Precaution, Pretection and Safety, all in FireTC
firetc@firetc.com
 
Post InformationYour location: Home » Offer » Firefighting Equipment »

Sell Type S DKL Aerosol Fire Extinguishing Device (Wall-mounted Series)

Click image to view original picture
Product/Service: Type S DKL Aerosol Fire Extinguishing Device (Wall-mounted Series)  
Demand Quantity:  
Price Requirement:   Inquiry
Size Requirement:
Package Requirement:
Address: China
Validity Period: Longterm Validity
Last Update: 2014-05-22
Browse: 2209
Basic Info of Company
 
 
Detailed Description

DKL systems provide highly effective, enviromentally friendly fire suppression for fires in enclosed facilities and local spaces

General Description

DKL TYPE-S AUTOMATIC AEROSOL FIRE EXTINGUISHING UNIT is a new class of fixed fire extinguishing system using solid propellant aerosol technology. Unlike conventional fire extinguishing systems, it is stored as a stable solid chemical compound which when activated generates a fire-fighting aerosol. The extinguishing medium however is not stored in a pressurised cylinder. The aerosol is a mixture of gases and micron-sized solids, possessing gas-like distribution properties and long holding times, totally floods the protected enclosure and rapidly extingsuies any fire present.

DKL fire suppression systems, can be characterized as requiring no piping, zero storage pressure, solid-state technology, environmentally friendly, non-conductive & non-corrosive, and has significant space & weight advantages in comparision with gaseous systems.

Technical Specification

Note:

According to < Aerosol Fire Extinguishing System> GA499.1-2004

The following details are a representative extract of the technical specification for HANGING series fire suppression system and may be subject to change. Complete and current details should be determined from the designated supplier's technical manual/data sheets.

Model JR2000 JR4000 JR6000 JR8000 JR100M
Aerosol Mass,g 2500 5000 7500 10000 12500
Generator Mass,kg 22 44 48 70 75
Max.Protected Volume,m³ 20 40 60 80 100
Dimensions,mm   Length 600 800 800 900 900
                           Diameter 220 300 300 350 350
Canister Material M/S M/S M/S M/S M/S
Nozzle Outlet D/Lateral D/Lateral D/Lateral D/Lateral D/Lateral
Discharge Time,sec  < 50  < 50  < 80  < 90  < 100

Fire Classes

According to < Code for Design of Gas Fire Extinguishing Systems> GB 50370-2005

-Class A: Electrical Appliance Fire

-Class B: Solid Surface Fire

-Class C: Liquid Fire

Minimum Design Factor:

Class B and surface Class A fire: 130g/m3 (Type S aerosol forming composition)

                                                  50g/m3 (Type K aerosol forming compositon)

Electrical activation:

-Starting current: 1A

-Starting voltage: 24 VDC

-Min. starting current: 500mA 5ms

-Max. safe current: 250mA 5min

-Linkage mode: series system

Canister Characteristics:

-Temperature range:  -20oC - +55oC

-Humidity range of application: 0 - 98% non-condensing

-Service life: ≤ 6 years (depends on installation environment)

-Vibration: 5g @ 50 - 250 Hz

Aerosol Characteristics:

-Minimum particle size: -1 micron

-Holding time: ≤ 60 mins

Typical Applications:

-cargo compartments

-data rooms

-electrical substations

-cable tunnels

-generator rooms

-intelligent buildings

-laboratories

-machinery spaces

-raised-floors

-telecommunications cabins

J&R Aerosol Fire Extinguishing Technology Benefits at a Glance

-spontaneous extinguishing action

-cost effective

-compact and weight saving

-tested and certified

-simple to install and recommission

-no pressurised cylinders or pipe work

-environmentally friendly

-low toxicity

 