EN 45545-2 Fire test to cable

Click image to view original picture
Product/Service: EN 45545-2 Fire test to cable 
Brand: Crepim 
Type: EN 45545-2 
Size: EN45545 
Unit Price: 7800.00USD/PCS  Inquiry
The min order: 1 PCS 
Total Supply: 8000 PCS
Delivery Expiry: Delivery within 3 days after payment from buyer
Validity Period: Longterm Validity
Last Update: 2014-08-15
Browse: 9359
Basic Info of Company
 
 
Product detailed description
 EN 45545-2 Fire test to cable 

Ecosafene Products Service Co.,Ltd provide EN45545-2 fire test to railway vehicles.

EN 45545-2 Fire test to cable- Standard

EN45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviours of materials and components - R15 / R16

EN 45545-2 Fire test to cable- General 

Electrical cables which satisfy the fire safety requirements of EN 50306, EN 50264 or EN 50382 are considered to satisfy the requirements of R15 and R16 for the corresponding hazard level (no further testing required).

EN 45545-2 Fire test to cable - Requirement 

EN 45545-2 R15 Cables for interior

Test Method

Requirement

HL1

HL2

HL3

EN 60332-1-2

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

EN 60332-3-24

(D≥12mm)

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.1

(6 < D < 12 mm)

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.2

(D ≤ 6 mm)

<1.5m

<1.5m

<1.5m

EN 61034-2

-

>25%

>50%

EN 50305

Clause 9.2 ITC

<10

<10

<6

 EN 45545-2 R16 Cables for exterior

Test Method

Requirement

HL1

HL2

HL3

EN 60332-1-2

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

burned part ≤ 540 unburned part > 50

EN 60332-3-24

(D≥12mm)

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.1

(6 < D < 12 mm)

<2.5m

<2.5m

<2.5m

EN 50305

Clause 9.1.2

(D ≤ 6 mm)

<1.5m

<1.5m

<1.5m

EN 61034-2

>25%

>50%

>70%

EN 50305

Clause 9.2 ITC

<10

<10

<6

 EN 45545-2 Fire test to cable Reference Standard

 EN 50306 Railway rolling stock cables having special fire performance

EN 50264 Railway rolling stock power and control cables having special fire performance

EN 50382Railway rolling stock high temperature power cables having special fire performance

EN 60332-1-2, Tests on electric and optical fibre cables under fire conditions — Part 1-2: Test for vertical flame propagation for a single insulated wire or cable — Procedure for 1 kW pre-mixed flame

EN 60332-3-24Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables -Category C

EN 61034-1, Measurement of smoke density of cables burning under defined conditions -Part 1: Test apparatus

EN 61034-2, Measurement of smoke density of cables burning under defined conditions - Part 2: Test procedure and requirements

EN 50305Railway rolling stock cables having special fire performance -Test methods

>> We work with fireTC and also can provide the following service of fire test 

> Fire test to railway components: BS 6853, DIN 5510-2, NF F 16-101, UNI CEI 11170-3, NFPA 130, EN 45545-2, UIC 564-2.

> Fire test to buidling material: EN 13501-1, DIN 4102, BS 476, NF P 92-501, GB 8624, GB 20286

> Fire test to marine equipment: IMO FTPC, Wheelmark, USCG

> Fire test to aircraft material: FAR 25, BSS 7239, BSS 7238, ASTM E 662

> Fire test to interior material of motor vehicles: 95/28/EC, GB 8410, FMVSS 302, ISO 3795

 
More..Other products of this company

[ Product Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]