 DIN EN 50305 / EN 50305 Toxicity test 

DIN EN 50305 Toxicity test - Standard 

DIN EN 50305 Railway applications-Railway rolling cables having special fire performance-Test methods, Clause 9.2 Toxicity 

DIN EN 50305 Toxicity test – Test conditions

Prior to testing, all test pieces was conditioned at least 48 h in an atmosphere having a temperature of 23±2°C and a relative humidity of 50±5%.

DIN EN 50305 Toxicity test - Requirement

According to DIN 5510-2 test standard,

Requirements :  I.T.C Values≤ 3(Refer to DIN EN 50264-1:2008) 

DIN EN 50305 Toxicity test - Critical Concentration

CCZ Values for varions gased

Gas

CCZ

Carbon Dioxide(CO2)

90 000

Carbon Monoxide(CO)

1750

Hydrogen Cyanide(HCN)

55

Nitrogen Oxides(NO2)

90

Sulphur Dioxide (SO2)

260

DIN EN 50305 Toxicity test – Reference Standard  

DIN5510-2 : Preventive fire protection in railway vehicles; Part 2: Fire behaviour and fire side effects of materials and parts, classification, requirement and test methods.

EN45545-2: Fire protection of railway vehicles - Part 2: Requirement for fire behaviours of materials and components

EN60332-3-24: 2010-08 Test on Electric and Optical Fibre Cables under Fire Conditions Part 3-24: Test For vertical flame spread of vertically---Mounted bunched wires or cables Category C (IEC 60332-3-24:2000 + A1:2008)

DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C

DIN EN 50266-2-4:: Common test methods for cable under fire condition—Test for vertical flame spread of vertically-mounted bunched wires or cables –Part 2-5: Procedures –Category C

DIN EN 50305: Railway applications. Railway rolling stock cables having special fire performance. Test methods

DIN EN 60332-1-2: Tests on electric and optical fibre cables under fire conditions Part 1-2: Test for vertical flame propagation for a single insulated wire or cable Procedure for 1 kW pre-mixed flame

DIN EN 61034-1: Measurement of smoke density of cables burning under defined conditions Part 1: Test apparatus

 
More..Other products of this company

[ Product Search ]  [ ]  [ Forword to friends ]  [ Print ]  [ Close ]  [ Back to Top ]