(b) Flammability UL94 V-0
(c) High tenacity
(d) Used for all kinds of pipe
Fire Proofing PE (for Pipe) PE-FR01P
Features
(1) Flammability UL94 V-0
(2) High tenacity
Application
(1) Injection molding
(2) Shell of Electrical Household Appliance
(3) Thermoplastic Casing Pipe
(4) Electric Pipe
Properties
Test Project |
Test Methods |
Unit |
Typical Values [1] |
Tensile Stress |
GB/T1040-92 |
Mpa |
50-70 |
Flexural Stress |
GB/T9341-2000 |
Mpa |
10-15 |
Flexural Modulus |
GB/T9341-2000 |
Mpa |
3200-3800 |
Notched Impact Strength |
GB/T1043-93 |
KJ/m2 |
≥10 |
Elongation At Break |
GB/T1040-92 |
% |
100-350 |
Heat Distortion Temperature |
GB/T1634-2004 |
°C |
45-70 |
MFR |
GB/T3682-2000 |
g/10min |
0.2-2 |
Flammability |
GB/T 2408-1996 |
V-0 |
|
Testing Condition |
23±2°C, 50±5%RH |
[1] Typical Values are average statistics in lab for reference. They are not used as products standards.
Processing Conditions
|
Start Point |
Range |
|
Melt Temp |
|
125°C |
110-140°C |
Barrel Zone Temp. |
Rear |
120°C |
110-130°C |
|
Center |
125°C |
120-135°C |
|
Front |
130°C |
125-140°C |
Mold Temp. |
|
30°C |
20-50°C |
Processing Temp. Limit |
|
140°C |
|
Injection Speed |
|
Moderate to High |
|
Pre-Dry Requirements |
|
60°C, 2h |
Note All the statistics above are for reference and can be adjusted according to different requirements